DW-B Vertical Autoclave

DW-B Vertical Autoclave

Advanced Functions of DW-GI Series Vertical Autoclave


1. Colorful LCD screen
LCD screen with English and Chinese choice, using text, data, and graphical methods to dynamically display various statuses, the sterilization process is clear at a glance.
2. 6 level of exhaust speed control(TW,TR,TP only)
After sterilization, you can choose different exhaust speed, and you can adjust it freely at any time of exhausting.
3. Condenser(Option)
Equipped with a professional condenser, the steam generated during the sterilization process is conve-rted into water through the condenser, achieving zero discharge of water vapor/mist.
4. F0 value caculation
FO value is automatic caculated, can print out by micro-printer.
5. Drying(TR only)
Fully automatic drying: Equipped with an air pump and a 0.2um air filter, it automatically starts drying after sterilization. After sterilization, clean air will be put in to replace the wet air inside, so as to improve drying efficiency. (Fully automatic drying is an option for TR only)
6. Vacuum pump(TP only)
OriDW-GInal imported vacuum pump from Germany, with good vacuum effect.
7. Biosafety function (TWS, TRS only)
Use a 0.2 μm PTFE filter packed in a housing to ensure that no biohazard aerosols, microorganisms and viruses are passing out through the filter during exhausting, so as to ensure the biology safety of the lab.
8. Vacuum drying(TP only)
Set drying temperature and time, and start vacuum drying after sterilization.
9. 5 level access permission
The operation permissions for instruments are divided into five levels, with each level of user
having an independent password and multiple IDs that can be assigned. Each level of user has limited access to certain usage permissions.
10. Fast cooling fan
To shorten cooling process after sterilization.
11. Auto water fill(Option)
Offer pipe and pump to connect to the direct water supply to achieve automatic water feeding, must be added while production.
12. Dedorization(TX only)
A unique odor treatment system that can absorb odors and remove smell generated during the sterilization process, ensuring fresh laboratory air.
13. Air inlet filter(TX, TP as standard, TR as option)
Filtration is higher than 99.99% in particles with diameter of 0.2 μm.
14. Monitor of exhaust filter(TWS, TRS only)
Exhaust filter is put inside a pressure resistant housing(stainless steel material) with an extra PT100 temperature sensor to monitor the temperature, so as to make sure the filter and housing are also being sterilized thoroughly, and will not lead to secondary biohazard pollution.
15. Fully automatic drying(TR only)
Equipped with an air pump and a 0.2um air filter, it automatically starts drying after sterilization. After sterilization, clean air will be put in to replace the wet air inside, so as to improve drying efficiency.